Filter Results By:

Products

Applications

Manufacturers

Showing results: 301 - 315 of 628 items found.

  • HEV & EV Power Tester

    EVd-40 - NuVant Systems, Inc.

    The EVd-40 Power Tester is a pre- and post-reconditioning tool for quality control of aftermarket HEV & EV battery production. The equipment integrates a “smart” charger (Sorensen XG 1700 or Kepco KLN 1500W) with NuVant Systems high power discharge electronics. The "power test" discharges battery packs at high power (10,000 watts), while tracking module voltages. The software monitors up to 40 module voltages at a time, identifying any weak modules. The "smart" charger performs charging constant current (CC), constant voltage (CV) and complex mixed mode constant current – constant voltage (CCCV) charging protocols at voltages up to 600 V. This enables recharge of any type of rechargeable battery.

  • Primary Current Injection Test Trolley

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.

  • Optically Isolated Measurement System

    IsoVu - Tektronix, Inc.

    IsoVu offers complete galvanic isolation and is the industry’s first measurement solution capable of accurately resolving high bandwidth, low voltage differential signals in the presence of large common mode voltages. The stand out feature of IsoVu™ is its best in class common mode rejection across the entire bandwidth. Accurate differential measurements rely on a measurement system’s bandwidth, rise time, common mode voltage, common mode rejection capability, and the ability to connect to smaller test points to characterize devices that are shrinking in size and increasing in performance. Despite these requirements, advancements in test and measurement for power testing, EMI testing, ESD testing, and remote measurement capability have been minimal at best and have not kept pace with changing requirements. While differential voltage probes have had modest performance gains in regard to bandwidth, these probes have failed to make any substantial improvements in regard to common mode rejection, and connectivity. IsoVu is a leap forward in technology and is the only solution with the required combination of high bandwidth, high common mode voltage, and high common mode rejection to enable these differential measurements.

  • Other Passive Probes

    Texas Co.

    Probes connect the input of the oscilloscope to test points on the device under test (DUT). There are many types, including: high impedance passive, low capacitance, single-ended active, differential active, high voltage, and current probes. This is the first in a series of three articles on probe selection and application, and will focus on passive probes. Part 2 and part 3 will address active probes and current probes, respectively.

  • Autoranging Digital Multimeter w/Bargraph

    HH2209 - Colluck Company Limited

    High Accuracy (Basic Accuracy 1.0%)Jumbo LCD display 3260 count, 21mm figure heigh with BaragraphAuto Ranging or Manual Ranging at your choiceHigher Voltage test up to AC 750V and DC 1000VHigher Current test up to 20AResistance test up to 30MΩTemperature test range from -4oF or 1832oFWide Frequency test range up to 300kHzDiode test, audible continuity check and Transistor testLow Battery Indication

  • Active Filter

    J2190A - PICOTEST Corp.

    The J2190A active filter presents a high impedance (approximately 150kOhms) minimizing the loading of the circuit being tested. The output impedance is 50 Ohms allowing low noise coaxial connections to all typical test equipment. The 0.1Hz-10Hz noise band is common for opamp measurements, voltage regulators and voltage references. Many application notes offer schematics of such a filter for test purposes. An engineer’s time is much too valuable to be spent building test equipment. We have created a 4th order high pass and 4th order low pass filter with an optimally flat response and 0dB gain. Additional filters can be cascaded for even sharper cutoff.

  • Battery Test and Analysis System

    BTAS-16 - JFM Engineering

    The task of testing an aircraft’s Nickel-Cadmium batteries is complicated and involved because of the high number of cell voltage readings that need to be taken during testing. Taking voltage readings from all 20 cells in the typical nickle-cadmium aviation battery multiple times is laborious and error prone, but must be done to properly estimate the condition of the battery under test.

  • Impulse-Calibration-System

    KAL1000 Series - Dr. Strauss Messtechnik GmbH

    The impulse calibration system KAL1000 is a modular system to perform tests on complete impulse voltage measuring systems and on digital recorders for the measurement of high impulse voltages and impulse currents. The modular design allows an optimal KAL-configuration depending on the actual application.Additional, this modularity allows to up-grade or modify and existing KAL1000 system in case of changing or additional requirements

  • Surge and Test Generator

    STG 600 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR STG 600. The STG 600 surge and test generator is a multifunctional cable fault locator for low voltage networks. The surge and test generator is used for cable testing as well as for precise location of high-resistive and intermittent faults in low voltage cables.* Specifically for use in low-voltage networks* High surge energy: 600 or 1000 J** Light, compact and transportable* Single systems for cable testing and faults location

  • Pulse Adapter

    CV30P650 - Frothingham Electronics Corporation

    The CV30 P650 test station is currently the highest voltage pulser in a series of exponential pulse generators that can be connected to our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. The CV30 P650 pulse adapter can produce a maximum current of 100A at up to 600V using exponential pulses up the 10/1000 waveform. The pulser is rated at 30KW from 300V to 650V. Voltage compliance at 100A is 600V. The station can also include all of the usual FEC200 tests in the same test program.

  • DWV/IR Test Systems

    Applied Relay Testing Ltd.

    When used in conjunction with ART's own parametric relay test systems such as the RT290, the RT900 offers high speed AC and DC Hipot (dielectric withstand voltage) and Leakage testing of relays or other multi-pin passive devices.

  • Analogue (1kV below) Insulation Tester

    1132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Digital Clamp-on DC/AC AMmeter / Multimeter

    HH2009 - Colluck Company Limited

    Large LCD display 6000 count with symbolic signs. Auto Ranging High Voltage test up to 600V DC and 600V AC. Higher Current test up to 600A AC/DC. Continuity check. DC A zero adjust function. Low Battery Indication. Data Hold and Auto-Off Function

  • Manual Ranging Digital Multimeter

    HH2205K - Colluck Company Limited

    Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 23.5mm figure heigh. Manual Ranging at your choice (19 Range). Rated CAT II 1000V. High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A (fuse protected)

  • Pocket Size Digital Multimeter

    HH2106 - Colluck Company Limited

    Basic Accuracy 1.2%. Jumbo LCD display 2000 count, 11mm figure height. Manual Ranging at your choice (6 Range). Manual Ranging at your choice. High Voltage test up to AC 500V and DC 200V. Resistance test up to 2000KΩ. Diode test. Independent 12V "A23" power supply

Get Help